Product Description

Since Electromagnetic Fields are nearly everywhere it may be impossible to totally avoid them. The EMF meter IMPULSE can help you to not only measure but also will alert about these potentially harmful levels, determine safe range and help to reduce exposure. It also helps you determine which appliances produce high level emissions and identify hotspots in your local environment. Device has an appealing and compact design, is pocket size and lightweight. High Quality 5 Axis (antenna sensors) allow IMPULSE EMF Meter to provide fast and accurate measurements of electromagnetic fields in the living and work environment. Electric and magnetic field are simultaneously and independently detected and measured, properly scaled and transformed into visual graphs and columns to indicate full magnitude of currents by each type. EMF meter has four viewing modes, depending on pre set intensity thresholds for audio and visual alerts: EMF in Live Building, EMF in Live Area, EMF of PC. Measurements are displayed in dynamic columns, separately for electric and magnetic fields; fourth viewing mode VIEW displays only dynamic numerical values for each of 5 Axis. Measurements carry from two orthogonal Axis (X, Y) for the electric field and from another three Axis (X, Y, Z) for magnetic field. Average measurement time is 500 ms, samples twice per second.

Preset Treshholds for Audio, Visual and Text Warning Triggers according to the Norm
Mode Electric Field Treshold, V/m Magnetic Field Treshold, u/T Average
EMF in Live Building 500 10 10
EMF in Live Area 1000 25 10
EMF of PC 25 0,25 40
VIEW no no 40

 MEASURE Mode Index

measuremode-impulse.png

  1. Real Time Measurement mode
  2. RMS value of electric field intensity along X and Y axis
  3. Electric field measurement units: kV/m (kilovolts per meter)
  4. Electric field intensity threshold for audible, color and text warning triggering (it is set according to the active norms)
  5. Graphic columns for display of instant electric field values along X and Y axis
  6. Information message about electric field level, according to the active norms
  7. RMS value of magnetic field intensity along X, Y and Z axis
  8. Magnetic field measurement units: uT (microtesla)
  9. Magnetic field intensity threshold for audio, color and text warning triggering (it is set according to the active norms)
  10. Graphic columns for display of instant magnetic field values along X, Y and Z axis
  11. Information message about magnetic field level, according to the active norms

 

VIEW Mode Indexviewmodeimpulse.png

  1. Electric field intensity value along X axis. Measurement unit: V/m (volts per meter)
  2. Graphic scale for output of electric field intensity value along X axis
  3. Electric field intensity value along Y axis. Measurement unit: V/m (volts per meter)
  4. Graphic scale for output of electric field intensity value along Y axis
  5. Magnetic field intensity value along X axis. Measurement unit: uT (microtesla)
  6. Graphic scale for output of magnetic field intensity value along X axis
  7. Magnetic field intensity value along Y axis. Measurement unit: uT (microtesla)
  8. Graphic scale for output of magnetic field intensity value along Y axis
  9. Magnetic field intensity value along Z axis. Measurement unit: uT (microtesla)
  10. Graphic scale for output of magnetic field intensity value along Z axis.

 

Display Limit in Column Filling in Differen Modes
Mode Electric Field Column Limit, V/m Magnetic Field Column Limit, u/T
EMF in Live Building 2000 25
EMF in Live Area 5000 50
EMF of PC 50 500
VIEW 3300 29-46

 

 Conversions

  • 1 G (gauss) = 100 uT (microtesla)
  • 1 uT (microtesla) = 0.01 G (gauss)

Instrument is equipped with 5 antenna sensors. Two for measurement of electric field along X and Y Axis and with three sensors for magnetic field measurements along X,Y,Z Axis The Axis correspondent to the Axis of thrdimensional orthogonal coordinate system. It is essential to analyze the instant values along individual Axis for the purpose of exact source identification 

axix.png

Features

 

  • EMF Meter IMPULSE SOEKS SPECIFICATIONS
    Measurable Electromagnetic Field Frequency Range, HZ  from 20 to 2 000
    Range of Magnetic Field (Magnetic Induction) intencity Amplitude Along X,Y,Z axis, A/m (uT)  from 0,004 to 12 (0,005 to 15)
    Range of Magnetiv Field (Magnetic Induction) intemsity mean Square Value, A/m (u/T)  from 0,008 to 20 (from 0,1 to 25)
    Maximum Permissible Relative Error Measurement of Magnetic Field Intencity,%  +/- 30
    Hardware Nonlineary of Measurement of Magnetic Field of 50 Hz in Frequency, not more than,%  7,0
    Range of Electric Field Intencity Amplitude Along X,Y, Z axis, V/m  from 10 to 1000
    Range of Electric Field Intensity Mean Square Value, V/m  from 17 to 1700
    Maximum Permissible Relative Error of Measurement of Electric Field Intensity, %  +/- 30
    Hardware nonlneary of Measurement of Electric Field Intensity in 50 Hz in Frequency, no more than, %  4,0
    Measurement Rate, Samples per Second  2
    Range of Supply voltage of Battery or Accumulator, V  1,8-3,3
    USB Supply Voltage, V  4,6 - 5,5
    USB Consumption Current, no more than,mA  300
    Accumulator Charging Current, no more than, mA  200
    Time of Continuous Work at least, Hours  10
    Overall Dimentions Height x Width X Depth, inches  4,5 x 1.8 x 0.7
    Weight, oz  2.1